Mitsubishi — 1.2.4 Inspecting output

ELECTRICAL SYSTEM 1.2.3 Inspecting regulated voltage (1) Disconnect the battery (+) terminal, and connect an ammeter. (2) Connect a volt meter to terminal L ground line. (3) Make sure that the volt meter indicates 0 when the starter switch is OFF position. Make sure that the volt meter indicates much lower voltage than battery voltage when the starter switch is ON position. (4) Disconnect the terminal of ammeter, and start the engine. (5) Measure the adjusting voltage with volt meter. Checking regulated voltage Ammeter Lamp Alternator A L R E Switch Battery B V Voltmeter 1.2.4 Inspecting output (1) Disconnect the battery ground cable.

(2) Connect B terminal of the alternator to the ammeter, then connect the voltmeter between B terminal and ground. (3) Connect the battery ground cable. (4) Start the engine. (5) Immediately apply all loads such as lamps. (6) Increase the engine speed and measure the maximum output current at the specified alternator rotation speed with the voltmeter indicated the specified value. (7) If the measured value meets the standard, the output is normal.

Inspecting regulated voltage Ammeter Voltmeter Lamp Alternator A Battery V L R B E Switch 12-5 Item Standard V-A Regulated voltage (at 20°C) [68°F] A007TA0171B 14.7±0.3 V 12-40 A 007TA8271A 28.5±0.5 V 24-25 Item Standard Terminal voltage/current Alternator rotation speed Output characteristics (when hot) A007TA0171B 13.5 V/21 A or higher 2500 min-1 13.5 V/37 A or higher 5000 min-1 A007TA8271A 27.0 V/18 A or higher 2500 min-1 27.0 V/22 A or higher 5000 min-1