Mitsubishi — 2.4.6 Measuring undercut depth

ELECTRICAL SYSTEM 2.4.4 Measuring commutator radial runout (1) Inspect the commutator surface. If the surface is rough, polish it using a 400 to 600 grit sandpaper. (2) Measure the commutator radial runout with a dial gauge. If the measured value exceeds the limit, replace the armature with a new one. Commutator Measuring commutator radial runout 2.4.5 Measuring commutator outside diameter Measure the commutator outside diameter. If the measured value is less than the limit, replace the armature with a new one. Outside diameter Measuring commutator outside diameter 2.4.6 Measuring undercut depth Measure the depth of undercutting between the commutator segments.

If the measured value is less than the limit, repair or replace with a new part. Undercut Segment Mica Measuring commutator mica depth 12-16 Item Commutator radial runout Standard 0.03 mm [0.0012 in.] Limit 0.10 mm [0.0039 in.] Item Standard Limit Commutator outside diameter 29.4 mm [1.158 in.] 28.8 mm [1.134 in.] Item Standard Limit Undercutting depth 0.5 to 1.0 mm [0.0197 to 0.0394 in.] 0.2 mm [0.0079 in.]