Mitsubishi — 2.6.2 Inspecting magnetic switch

ELECTRICAL SYSTEM 2.6.2 Inspecting magnetic switch Perform the inspection as described below. If faulty, replace the magnetic switch with a new one. &$87,21 Do not apply current continuously for longer than 10 seconds. 㧹 㧿 㧙 Battery 8 (1) Disconnect the connector of M terminal. (2) Pull-in test Connect the starter to the circuit as shown in the illustration. The magnetic switch is normal if the pinion springs out when the switch is turned ON. Pull-in test (3) Holding test Connect the starter to the circuit as shown in the illustration. Pull out the pinion fully by hand. The magnetic switch is normal if the pinion does not return when it is released. Disconnect the connector.

Starter Disconnect the connector. 㧿 㧹 Battery 8 Starter Holding test (4) Return test Connect the starter to the circuit as shown in the illustration. Pull out the pinion fully by hand. The magnetic switch is normal if the pinion returns immediately when it is released. Disconnect the connector. 㧹 Battery 8 Starter Return test 12-24