ELECTRICAL SYSTEM 2.8 Inspecting and repairing starter (M002T66071 (24V-3.2kW)) 2.8.1 Inspecting brushes for wear Measure the length of the brushes. If the measured value is less than the limit, replace both the brush holder assembly and the brush assembly with new ones. Measure the length of the brush. Replace if the length is equal to or less than the limit. Inspecting brushes for wear 2.8.2 Measuring brush spring load Using a new brush, measure the spring load at which the spring lifts from the brush. If the measured value is less than the limit, replace the spring with a new one.
Measuring brush spring load 2.8.3 Inspecting brush holder for insulation Check that there is no continuity between each brush holder and the brush holder base. If continuity is observed, replace the whole brush holder assembly. Check the brush holders for looseness. Insulated brush holder Brush holder base Checking brush holder for grounding 12-30 Item Standard Limit 18 mm [0.709 in.] Item Standard Limit Brush spring load 28.9 to 39.1N {2.95 to 3.99kgf} [6.5035 to 8.7963 lbf] 20N {2.04kgf} [4.4974 lbf]