ELECTRICAL SYSTEM 2.11 Inspecting and repairing alternator 2.11.1 Inspecting rectifier Check that diodes in a rectifier function properly. To check, measure both negative (-) and positive (+) resistance alternately twice. If both infinite negative and infinite positive resistances are observed, the diode is open- circuited. If measured value is close to 0 Ω , the diode is short-circuited. In either case, replace the rectifier with a new one. Note: Use a wide measuring range as much as possible.
The current flow during test is significantly lower than the current that normally flows in the rectifier, by which the accurate resistance may not be measured using a tester, and this tendency is noticeable if the measuring range is small. Checking rectifier 2.11.2 Inspecting rotor (1) Check that there is continuity between slip rings. If no continuity is observed, replace the rotor with a new one. Inspecting field coils for continuity (2) Check that there is no continuity between the slip ring and the shaft (or the core). If continuity is observed, replace the rotor with a new one. Checking field coils for grounding 12-42