ELECTRICAL SYSTEM 2.11.3 Inspecting stator (1) Checking continuity between lead wires Check that there is continuity between a pair of lead wires. Also check that there is no continuity between a pair of lead wires and other pair of lead wires. If defective, replace the stator. (2) Checking insulation between lead wire and core Check that there is no continuity between each lead wire and the stator core. If continuity is observed, replace the stator. Note: The core cannot be replaced as a single item. Checking for continuity between leads Checking for grounding between the leads and the core 2.11.4 Inspecting brushes for wear Measure the length of the brushes.
If the measured value is less than the limit, replace both the brush holder assembly and the brush assembly with new ones. Wear limit line Inspecting brushes 12-43 Item Standard Limit 18.5 mm [0.7283 in.]