Mitsubishi — 1.7 Electrical system

SERVICE DATA Table 2-7 Maintenance service data table - Electrical system(2 / 3) Unit:

mm [in.] 2-8 Inspection point Nominal Standard Limit Remark Starter M002T66071 (24V - 3.2kW) Pinion shaft end play 0.5 [0.0197] Pinion gap 0.5 to 2.0 [0.0197 to 0.0787] Brush length 18 [0.709] 11 [0.4331] Brush spring load 34 N {3.47 kgf} [2 lbf] 28.9 to 39.1 N {2.95 to 3.99 kgf} [6.5035 to 8.7963 lbf] 20 N {2.04 kgf} [4.4974 lbf] Commutator radial runout 0.03 [0.0012] 0.10 [0.0039] Commutator outside diameter ø 32.0 [1.2598] ø 31.4 [1.2362] Depth of undercuts between segments 0.5 [0.020] 0.4 to 0.6 [0.0158 to 0.0236] 0.2 [0.0079] or less No-load characteristics Terminal voltage 23 V Current 80 A or less Rotation speed 3400 min-1 or more Alternator A007TA0171B (12V - 40A) Brush spring load 4.8 to 6.0 N {0.49 to 0.61 kgf} [1.1 to 1.3 lbf] 2.2 N {0.22 kgf} [0.5 lbf] Brush length 18.5 [0.7283] 5.0 [0.197] Resistance between slip rings 2.95 Ω 2.7 to 3.2 Ω Slip ring outside diameter ø 22.7 [0.8937] ø 22.1 [0.8701] Output charac- teristics (when hot) 2500 min-1 Terminal voltage 13.5 V Current 21 A or more 5000 min-1 Terminal voltage 13.5 V Current 37 A or more IC regulator adjusting voltage (at 20°C [68°F] ) 14.7 ± 0.3 V Alternator A007TA8271A (24V - 25A) Brush spring load 4.8 to 6.0 N {0.49 to 0.61 kgf} [1.1 to 1.3 lbf] 2.2 N {0.22 kgf} [0.5 lbf] Brush length 18.5 [0.7283] 5.0 [0.197] Resistance between slip rings 12.4 Ω 11.4 to 13.4 Ω Slip ring outside diameter ø 22.7 [0.8937] ø 22.1 [0.8701] Output characteristics (when hot) 2500 min-1 Terminal voltage 27.0 V Current 18 A or more 5000 min-1 Terminal voltage 27.0 V Current 22 A or more IC regulator adjusting voltage (at 20°C [68°F] ) 28.5 ± 0.5V