Mitsubishi — 1.7 Electrical system

SERVICE DATA 1.7 Electrical system Table 2-7 Maintenance service data table - Electrical system(1 / 3) Unit:

mm [in.] 2-7 Inspection point Nominal Standard Limit Remark Starter M000T60481 (12V-1.2kW) Pinion clearance 0.5 to 2.0 [0.0197 to 0.0787] Brush length 16.5 [0.650] 10.0 [0.394] Brush spring load 20.58 N {2.10 kgf} [4.6 lbf] 17.5 to 23.7 N {1.78 to 2.42 kgf} [3.92 to 5.34 lbf] 6.86 N {0.70 kgf} [1.54 lbf] Commutator radial runout 0.03 [0.0012] 0.10 [0.0039] Commutator outside diameter ø 29.4 [1.158] ø 28.8 [1.134] Depth of undercuts between segments 0.75 [0.030] 0.5 to 1.0 [0.0197 to 0.0394] 0.2 [0.0079] or less No-load characteristics Terminal voltage 11 V Current 90 A or less Rotation speed 2500 min-1 or more Starter M001T68381 (12V-1.7kW) Pinion clearance 0.5 to 2.0 [0.0197 to 0.0787] Brush length 16.5 [0.650] 10 [0.394] Brush spring load 20.58 N {2.10 kgf} [4.6 lbf] 17.5 to 23.7 N {1.78 to 2.42 kgf} [3.92 to 5.34 lbf] 6.86 N {0.70 kgf} [1.54 lbf] Commutator radial runout 0.03 [0.0012] 0.10 [0.0039] Commutator outside diameter ø 29.4 [1.158] ø 28.8 [1.134] Depth of undercuts between segments 0.75 [0.030] 0.5 to 1.0 [0.0197 to 0.0394] 0.2 [0.0079] or less No-load characteristics Terminal voltage 11 V Current 110 A or less Rotation speed 2400 min-1 or more