Komatsu — EVERY 1000 HOURS SERVICE

. MAINTENANCE SERVICE PROCEDURE LUBRICATING PARKING BRAKE WARNING NOTICE possible to release the abnormal internal pressure caused by over-supply of grease. 4 - 68 When carrying out maintenance, raise the br ake oil pressure sufficiently to prevent the parking brake from being automatically applied. In add ition, hang a warning tag that can be seen clearly to prevent any other person from op erating the parking brake switch. Do not get any oil or grease on the brake dis 1. Stop the machine on level ground to the ground surface. and lower the bucket horizontally 2. Set the wor k equipmentlock lever and steering lock lever to the LOCK posi tion. 3.

Put blocks under the tires to prevent th e machine from moving. 4. Before sta rting operations, raise th to prevent the parkin e brake oil pressure g brake from being sufficiently automatica lly applied. Check also tha t the brake oil pressure warning pil ot lamp and central cautio n lamp (CAUTION) are does not sound. e engine. ase through fittings (1), not flashing and that the alarm buzzer 5. Release th e parking brake and stop th 6. Using the g rease pump, pump in gre (2), (4), an d (5) (4 places) on the p arking brake body and ack adjuster. fittings (3) a nd (6) (2 places) on the sl Do not use air pre ssure or oil pressure to carry o ut high-pressure greasing. 7.

After compl eting the greasing, remove If grease co mes out, wipe it off. REMARK Removing fittin gs (1) and (4) makes it 8. 9. When no m Check the ore grease comes out, ins braking capacity. For BRAKE (PAGE 4-51)". tall fittings (1) and (4). details, see "CHECK g the braking capacity, PARKING 10. If the mach ine moves when checkin please ask brake. your Komatsu distributor to adjust the parking