Komatsu — CHECK AND ADJUST AIR CONDITIONER

. MAINTENANCE SERVICE PROCEDURE CHECK AND ADJUST AIR CONDITIONER CHECK LEVEL OF REFRIGERANT(GAS) WARNING 4 - 40 CHECK TENSION OF COMPR ESSOR BELT If t he belt is loose, it will slip and will not be able to carry ou t cooling properly. Check the belt tension fro m time to time. The deflection s hould be 10 mm (0.4 in) when press ed at a point midway between the drive pulley (1) and compressor pulley (2) with a finger force o f approx. 58.8 N (6 kg). When the V-belt is new, it after 2 or 3 days.

will stretch at first, so always adjust it When handling refrigerant gas, always follow local laws and regulation The refrigerant used in the cooler is colorless and odorless a nd does no t harm the atmosp here, but if the liqui d gets int o your eyes or on your hands, it m ay cause loss of sight or frostbite , so never loosen any part of the refrigerant circ If t he level of the refrigera nt (gas) is low, the cooling effe ct will be reduced. Run the engine at high idle, and check the flo w of t he refrigerant gas (R134a) in the refrigerant circuit through the sight glass (2) (inspection windo w) of the receiver (1) when the cooler is running at high speed. (A) Correct: No bubbles (B) Low:

Bubbles are in (bubbles pass (C) None: Colorless, tra REMARK When there are bubble s, the refrigerant gas level is low, so contact your refrigerant dealer to have refrigeran contact added. If the air conditi oner is run with the refrigerant gas level low, it will cause damage to the c ompress New Freon R134a is us