Komatsu — BEFORE STARTING ENGINE

. OPERATION MACHINE OPERATIONS AND CONTROLS Check for Water and Sediment in Water Separator, Drain Water drain water under drain hose (3). 3. Loosen drain valve (4) and drain the water. 4. When fuel starts to drain from drain hose (3), tighten drain valve (4) immediately. REMARK If transparent cap (2) is dirty or it is difficult to see the inside, clean transparent cap (2) when replacing fuel pre-filter cartridge (1). When the drain valve (4) has been removed during the cleaning operation, coat the O-ring with grease and tighten until it contacts the bottom. 3 - 78 1. Open the cover on the right side of the machine rator forms one unit with fuel pre-filter ( 2.

It is possible to jud ge the water level and amou nt of sediment transparent cap (2). If there i s any wate r or d at the bottom, set a contain er to catch the On this machine, a sensor is installed to detect if water is arent cap (2). accumulated in transp When the water separ ator monitor (5) lights up red o n the machine monitor, it indicates th (2). In this case also, use at water is accumulated in transparent cap the procedure above to drain the water. ansparent cap NOTICE ted in transparent cap (2) freezes, the water separator monitor may not light up. After the engine is If the water accumula t up. After the en gine is started, as the temper suddenly light up.

In ature around fuel pre-filter (1) inc reases, the froze n wat er will melt and the wat er separator monit or may cold areas, even if the water sepa rator monit or does n ot light up, drain the wa ter frequently. If the water inside tran sparent cap (2) freezes, check tha t the frozen water has melted completely, then use the procedure above to drain the water.