Detroit Diesel — Engine Data List

Appendix A • Parameter Listings 148 Detroit Diesel Application User’s Manual Parameter Description • R2 VSG CNTS (STANDARD) • R2 THROT CNTS (MARINE) Indicates the receiver ECM #2 (MID 183) Variable Speed Governor (VSG) - A/D counts. For marine engines, indicates the main throttle counts. “N/A” will be displayed if the A/D port mask for PTO position is disabled as indicated by DDEC Unique ID 223. REL HUMID Indicates relative humidity. “FAIL” will display if FMI 3 or FMI 4 is received. SEQ TURBO Indicates the status of the Sequential Turbo Mode. SPD ADJUST MPH Indicates the adjusted vehicle road speed in MPH or KPH.

SRS RECEIVED Indicates that the ECM has received a signal from the Synchronous Reference Sensor (SRS) during the ignition cycle. SHUTDOWN Indicates whether the engine has been shutdown by the idle shutdown feature. START RLY Indicates the status of the optimized idle starter relay. SYS ACTIVE Indicates the active status of the optimized idle system. THROTTLE PLATE Indicates the percent opening of the natural gas throttle plate. TIMER Indicates the active/inactive status of the idle shutdown timer. TORQ LB-FT Indicates the amount of torque available at the engine flywheel. Negative torque values will display with a minus sign (-) in front of the value.

TPS CNTS (STANDARD) Indicates the Throttle Position Sensor (TPS) Counts (CTS) - A/D Counts. For marine engines indicates the alternate. • TPS PCT (STANDARD) • ALT THROT PCT (MARINE) Indicates the percent opening of the throttle position sensor (TPS). For marine engines indicates the percent opening of the alternate throttle. “FAIL” will be displayed if a FMI 3 or FMI 4 is received. “N/A” will be displayed if the A/D port mask for Throttle Position is disabled as indicated by DDEC Unique ID 223. TRB CMP OUT Indicates turbocharger compressor outlet tempera- ture in degrees Fahrenheit or Celsius. “FAIL” will display if FMI 3 or FMI 4 is received.