Detroit Diesel — Engine Rating Calibration

DDEC Engine Parameters 1 User changes to “ECON”, “MAX SPEED” or “MINIMUM MPG” ultimately result in a re-calibration of the conversion factor programmed into the ECM. The valid range for the ECON parameter shifts with changes to either MINIMUM MPG or MAX SPEED. This range is calculated as follows:

Minimum ECON = (MAX SPEED / max allowable conversion factor) + MINIMUM MPG Maximum ECON = (MAX SPEED / min allowable conversion factor) + MINIMUM MPG As of this printing, the valid ECM range for conversion factor is 0.1 - 20.0 mph/ mpg) If MPH or MPG are modified such that the currently entered ECON value falls out of its updated valid range, then ECON defaults to its minimum or maximum value for the updated range. Engine Rating Calibration The following table lists all reprogrammable Engine Rating parameters. Detroit Diesel Application User’s Manual 181 Parameter Value Range Definition #1 XXX @ XXXX 0 to 999 BHP, 0 to 999 KW, 0 to 9999 RPM A standard rating is displayed as XXX @ YYYY.

Where XXX = BHP and YYYY = RPM. A cruise rating is dis- played as XXX/XXX @ YYYY. “N/A” will be displayed if the engine rating #1 is unavailable. #2 XXX @ XXXX 0 to 999 BHP, 0 to 999 KW, 0 to 9999 RPM A standard rating is displayed as XXX @ YYYY. Where XXX = BHP and YYYY = RPM. A cruise rating is dis- played as XXX/XXX @ YYYY. “N/A” will be displayed if the engine rating #2 is unavailable. #3 XXX @ XXXX 0 to 999 BHP, 0 to 999 KW, 0 to 9999 RPM A standard rating is displayed as XXX @ YYYY. Where XXX = BHP is dis- played as XXX/XXX @ YYYY. “N/A” will be displayed if the engine rating #3 is unavailable.