Detroit Diesel — Engine and Vehicle Options

Appendix A • Parameter Listings 180 Detroit Diesel Application User’s Manual Parameter Description FUEL ECON This feature will add a MPH delta to the INCENTIVE cruise and road speed maximums based on average fuel economy. The feature is intended to provide incentive to the driver to operate the vehicle in such a way as to maximum MPG. MINIMUM MPG1 Indicates the minimum MPG (or Maximum L/100 K) threshold to enable the cruise and road speed adjustment feature that is programmed in the DDEC calibration. MAX SPEED1 Indicates the maximum adjustment value for cruise and road speed adjustment that is programmed in the DDEC calibration. ECON1 Fuel economy for maximum speed delta adjustment.

Indi- cates the calculated MPG (or L/100km) for the maximum speed adjustment value. This parameter is calculated using the programmable parameters “MINIMUM MPG”, “MAX SPEED”, and the current value given by the engine controller for conversion factor (formerly the MPC dis- played parameter “SCALER”). The calculation is: ECON = (MAX SPEED / conversion factor) + MINIMUM MPG. CALC TYPE Indicates the speed adjustment calculation type that is programmed in the DDEC calibration. The speed adjust- ment can be calculated from short term MPG or long term MPG. IDLE METHOD Indicates which method will be used to determine if the engine is on idle for the purpose of idle data accumula- tion.

Requires VSS ENABLED = NO. LOAD LIMIT % If IDLE METHOD is RPM/LOD, displays the load limit under which idle data will be accumulated. RPM LIMIT If IDLE METHOD is RPM/LOD, displays the RPM limit under which idle data will be accumulated.