Appendix A • Parameter Listings Marine Controls Historic Codes The following table lists the parameters available for Historic Codes. 202 Detroit Diesel Application User’s Manual Parameter Description Marine Controls version 2.0 and 2.5 PORT PRESS SWITCH Port Pressure Switch is not closed when it should be. STBD PRESS SWITCH Starboard Pressure Switch is not closed when it should be. PORT GR SOLENOID Port Gear Actuator solenoid is not energized when it should be. STBD GR SOLENOID Starboard Gear Actuator solenoid is not energized when it should be. LOW CSIM VOLTS Active CSIM voltage low. PORT TROLL NOT ENG Port transmission not fully engaged, still in troll mode.
STBD TROLL NOT ENG Starboard transmission not fully engaged, still in troll mode. Marine Controls version 3.0 NO ERROR CODES – LOW VOLTAGE @CSIM Voltage supply at CSIM is low. ACTUATOR LOW VOLTS Voltage supply at actuator is low. ACTIVE CSIM COM LOSS Active CSIM is not responding. MSTR CSIM COMM LOSS Master CSIM is not responding. CSIM 2 COMM LOSS CSIM #2 is not responding. CSIM 3 COMM LOSS CSIM #3 is not responding. CSIM 4 COMM LOSS CSIM #4 is not responding. CSIM 5 COMM LOSS CSIM #5 is not responding. CSIM 6 COMM LOSS CSIM #6 is not responding.