COMPONENT OPERATION / Pump Device Regulator Control Function The regulator has the following four control functions. Control by Pump Control Pressure When a control lever is operated, the pump flow rate control valve in signal control valve regulates pump control pressure Pi in response to the lever stroke. When the regulator receives pump control pressure Pi, the regulator controls the pump delivery flow rate in proportion to pump control pressure Pi. When a control lever is operated, pump control pressure Pi increases and the regulator increases the pump delivery flow rate.
When the control lever is returned to neutral, pump control pressure Pi decreases and the regulator decreases the pump delivery flow rate. Flow Rate (Q) Pump Control Pressure (Pi) 0 Control by Own or Opponent Pump Delivery Pressure The regulator receives own pump delivery pressure Pd1 and opponent pump delivery pressure Pd2 as control signal pressures. If the two average pressures increase over the set P-Q line, the regulator reduces both pump delivery flow rates and the total pump output is returned to the set P-Q line. Thereby, the engine is protected from being overloaded.
As the P-Q line has been designated in order to jointly regulate both pump operations, both pump delivery flow rates are regulated almost equally to each other. Accordingly, although the higher-pressure side pump is loaded more than the lower-pressure side pump, the total pump output matches with the engine output. (Total Output Control) Flow Rate (Q) Pressure (P) 0 Control by Pilot Pressure from Torque Control Solenoid Valve The main controller (MC) operates based on both the engine target speed input data and actual speed information signals and outputs the signals to the torque control solenoid valve.
In response to the signals from MC, the torque control solenoid valve delivers torque control pilot pressure Pps to the regulator. When receiving pilot pressure Pps, the regulator reduces the pump delivery flow rate. (Speed Sensing Power Decrease Control: Slow Speed Torque Increase Control) (Refer to the Control System group.) Flow Rate (Q) Pressure (P) 0 T3-1-8 Pressure Increas Flow Rate De