hitachi — Regulator

COMPONENT OPERATION / Pump Device Control by Pilot Pressure from Maximum Pump Flow Rate Limit Control Solenoid Valve (ZX160- 3 class : Pump 1 and Pump 2) (ZX180- 3 class : Pump 2 Only) When the main controller (MC) receives the signals from the work mode switch, pressure sensor [auxiliary] or attachment mode switch (optional), MC sends the signals to the maximum pump flow rate limit control solenoid valve. In response to the signals from MC, the maximum pump flow rate limit control solenoid valve reduces pump control pressure Pi. Therefore, the upper limit pump delivery flow rate is limited.

(Pump Flow Rate Limit Control) (Refer to the Control System group.) Flow Rate (Q) 0 Pressure (P) Maximum Flow Rate Flow Rate (Q) Upper Limit Flow Rate Pressure (P) 0 Dr Pi Pd2 Air Bleeding Circuit Pps Pd1 Dr Increase Decrease Pg T1V1-03-01-005 Cylinder Block Inclination Pd1 -Pump 1 Delivery Pressure Pi - Pump Control Pressure Pd2 - Pump 2 Delivery Pressure Pps -Torque Control Pressure Dr - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-9