COMPONENT OPERATION / Pump Device Control by Pump Control Pressure Increasing Flow Rate 1. When a control lever is operated, the flow rate control valve in signal control valve is shifted and pump control pressure Pi increases. 2. Piston (4) pushes spool A (3) and spring (1) so that spool A (3) is moved toward direction of the arrow. 3. By this movement, the circuit from the large chamber of servo piston (11) is opened to the hydraulic oil tank. 4. As pilot pressure is always routed into the small chamber of servo piston (11), servo piston (11) is moved toward direction of the arrow.

Then, the cylinder block is rotated in the maximum inclination direction and the pump delivery flow rate increases. 5. The movement of cylinder block is transmitted to sleeve A (2) via link (13). Sleeve A (2) is moved in the same direction as spool A (3). 6. When sleeve A (2) is moved by the same stroke as spool A (3), the open part between spool A (3) and sleeve A (2) is closed and the circuit from large chamber of servo piston (11) to the hydraulic oil tank is closed. Therefore, servo piston (11) is stopped and the flow rate increasing operation is completed.

Flow Rate (Q) Pump Control Pressure (Pi) 0 Pi Pd1 Air Bleeding Circuit Pps Dr Pd2 T1V1-03-01-005 Increase Decrease Cylinder Block Inclination 1 - Spring 4 - Piston 2 - Sleeve A 11 - Servo Piston 3 - Spool A 13 - Link Pd1 -Pump 1 Delivery Pressure Pi - Pump Control Pressure Pd2 - Pump 2 Delivery Pressure Pps -Torque Control Pressure Dr - Returning to Hydraulic Oil Tank Pg - Primary Pilot Pressure (From Pilot Pump) T3-1-10 1 3 2 4 Dr Dr Pg 11 13