hitachi — Valve Unit

COMPONENT OPERATION / Swing Device Relief Valve During starting or stopping swing operation, oil pres- sure in the swing circuit becomes high. The relief valve prevents the circuit pressure from rising higher than the set-pressure. ZX160-3 class Low Pressure Relief Operation (Shockless Func- tion): 1. Pressure at port HP (swing circuit) is routed to oil chamber C through the poppet orifice. 2. Pressure oil in oil chamber C is further routed to oil chambers A and B via passages A and B re- spectively. 3. The pressure receiving area in oil chamber B is larger than oil chamber A so that the piston moves to the left. 4.

As long as the piston keeps moving, a pressure difference is developed between the front and the rear of poppet. When this pressure difference is increased more than spring force, the poppet is unseated, pressure oil flows to port LP. 5. When the piston is moved to full stroke, the pres- sure difference between the front and the rear of poppet disappears and the poppet is seated. High Pressure Relief Operation (Overload Preven- tion): 1. After the piston is moved to full stroke, the spring is compressed so that the circuit pressure be- comes the set-pressure. 2. If pressure at port HP increases more than the spring set-pressure, the poppet is unseated and pressure oil flows to port LP. 3.

When pressure at port HP is reduced to the specified level, the poppet is seated by the spring force. Orifice Spring Poppet Passage A Passage B Piston HP LP T178-03-02-005 Oil Chamber C Oil Chamber A Oil Chamber B T3-2-8