hitachi — Pilot Shut-Off Valve

COMPONENT OPERATION / Others (Upperstructure) Pilot Shut-Off Lever: LOCK Position 1. When the pilot shut-off lever is in the LOCK position, the pilot shut-off relay is turned OFF and the pilot shut-off solenoid valve is turned OFF. (Refer to Electrical System/ SYSTEM.) 2. Pressure oil from the pilot pump is blocked by the spool in pilot shut-off solenoid valve. 3. Oil to the pilot valve and signal control valve sides flow to the hydraulic oil tank. 4. Therefore, although the control/travel lever is operated, the pilot valve is not operated. Pilot Shut-Off Lever: UNLOCK Position 1.

When the pilot shut-off lever is in the UNLOCK position, the pilot shut-off relay is turned ON and the pilot shut-off solenoid valve is activated. (Refer to Electrical System/ SYSTEM.) 2. Therefore, the drain circuit is blocked by the spool in pilot shut-off valve. 3. Pressure oil from the pilot pump flows to the pilot valve and signal control valve. 4. Consequently, when the control/travel lever is operated, the pilot valve is operated. Pilot Shut-Off Lever: UNLOCK Position To Ports T1 to T4 From Pilot Pump To Ports A1 to A4 Spool T1V1-03-07-012 T3-7-2