Optimized Idle User Manual OPERATING INFORMATION The following describes the Operating Information. USING DDEC Reports DDEC software allows the ECM to collect and store operating data known as DDEC Reports. Optimized Idle information is included. DDEC Reports extracts the data when the PC is plugged into the vehicle's diagnostic connector. DDEC Reports DDEC Reports analyzes and reports the Optimized Idle data for a specific trip, monthly activity and life--to--date as listed in the Table. Table 3.
PASSWORD PROTECTION FOR THERMOSTAT SETTINGS The Optimized Idle thermostat settings are protected by a password that can be installed by the fleet management, refer to the thermostat reprogramming guide, 18SA366 or call the Detroit CSC for further assistance with this. PROGRAMMING LIMITS AND NEW PASSWORD Specific parameters in the thermostat can be modified to meet the customer’s requirements. A password is required to change the following: All information subject to change without notice. 19 DDC-SVC-MAN-0019 Copyright © 2016 DETROIT DIESEL CORPORATION Optimized Idle Time Active Amount of time the Optimized Idle system is enabled.
Run Amount of time the engine is running in Optimized Idle Mode. Battery Amount of time the engine is running for the battery voltage. Engine Temp Amount of time the engine is running for oil temperature. Thermostat Amount of time the engine is running for the cab temperature. Extended Idle Amount of time the engine is running in Extended Idle Mode. Continuous Amount of time the engine is running in Continuous Mode.