UEN00099-00 10 Structure, function and maintenance standard Action of spring q Load of springs (4) and (6) on the PC valve is determined by the swash plate position. q Self pressure (PP1) enters port (B) and the small diameter end of servo piston (9), and other pump pressure (PP2) enters port (A). q As servo piston (9) moves to right, spring (6) is retracted. q When pump pressures (PP1) and (PP2) are small, spool (3) will be positioned in the left side. q If the servo piston moves further, it will be con- tacted again seat (5) and spring (6) will be fixed. q Port (C) and (D) are connected, and the pres- sure entering the LS valve becomes drain pressure (PT).
q After that, spring (4) alone will operate. q The spring load is changed by servo piston (9) as it extends or compresses springs (4) and (6). The spring load changes as the servo piston (9) extends and contracts the springs (4) and (6). q If port (E) and port (G) of the LS valve are con- nected, the pressure entering the large diame- ter end of the piston from port (J) becomes drain pressure (PT), and servo piston (9) moves to the left side. q If the command current (X) to PC-EPC valve solenoid (1) changes, so does the force push- ing piston (2). q The pump delivery will be set to the increasing trend.
q Accompanied with move of servo piston (9), springs (4) and (6) will be expanded and the spring force becomes weaker. q Spring load of springs (4) and (6) is also affected by the command current (X) to PC- EPC valve solenoid. q Port (C) of the PC valve is connected to port (E) of the LS valve. 20 PC210, 230, 240-8