Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Hydraulic pump

10 Structure, function and maintenance standard UEN00099-00 q As the spring force is weakened, spool (3) moves to the right, the connecting between port (C) and port (D) is shut off and the pump discharge pressure ports (B) and (C) are con- nected. q As a result, the pressure on port (C) rises and the pressure on the large diameter end of the piston also rises. Thus, the leftward move of servo piston (9) is stopped.

q Servo piston (9) stop position (= Pump deliv- ery) is decided by the position where the push- ing force generated from the pressures (PP1) and (PP2) applied to spool (3), the pushing force of the solenoid in PC-EPC valve gener- ates and the pushing force of springs (4) and (6) are balanced. PC210, 230, 240-8 21