UEN00099-00 10 Structure, function and maintenance standard (2) When load on actuator is large and pump discharge pressure is high Outline q When the load is large and pump discharge pressures (PP1) and (PP2) are high, the force pushing spool (3) to the right becomes larger and spool (3) will be moved to the position shown in above figure. q When servo piston (9) moves to the right, springs (4) and (6) are compressed and push back spool (3). q When spool (3) moves to the left, the opening of port (C) and port (D) becomes larger. q Part of the pressure to be conducted from port (C) to LS valve flows from port (B) to port (C) and (D) via LS valve.
At the end this flow, level of this pressure becomes approximately half of the main pump pressure (PP2). q As a result, the pressure on port (C) (= J) is decreased and the rightward move servo pis- ton (9) is stopped. q The position in which servo piston (9) stops at this time is further to the right than the position when pump pressures (PP1) and (PP2) are low. Operation q The relationship between the average pump pressure (PP1 + PP2)/2 and servo piston (9) in terms of their positions can be represented by the broken line in the figure springs (4) and (6) form the double springs.
q When port (E) and port (G) of the LS valve are connected, this pressure from port (J) enters the large diameter end of servo piston (9), stopping servo piston (9). q If main pump pressure (PP2) increases further and spool (3) moves further to the right, main pump pressure (PP1) flows to port (C) and acts to make the pump delivery the minimum. 22 PC210, 230, 240-8