10 Structure, function and maintenance standard UEN00099-00 q The relationship between the average pump pressure (PP1 + PP2)/2 and average pump delivery (Q) becomes as shown below. q If command voltage (X) sent to PC-EPC valve solenoid (1) increases further, the relationship between average pump pressure (PP1 + PP2)/ 2, and pump delivery (Q) is proportional to the force of the PC-EPC valve solenoid and moves in parallel.
q Namely, the force of PC-EPC valve solenoid (1) is added to the pushing force to the right because of the pump pressure applied to the spool (3), so the relationship between the aver- age pump pressure (PP1 + PP2)/2 and the pump delivery (Q) moves from (A) to (B) as the command current (X) is increased. PC210, 230, 240-8 23