UEN00099-00 10 Structure, function and maintenance standard 2) As the emergency pump drive switch is turned on due to failure on the pump controller (1) When the main pump is under light load q If there is a failure in the pump controller, the emergency pump drive switch is turned on to hand the control to the resistor side. q Since the pressure on the small diameter end of the piston large, servo piston (9) moves in the direction to make the discharge amount larger. q In this case, the power is directly supplied from the battery. The current, however, is too large as is, so the resistor is set in between to con- trol the current flowing to PC-EPC valve sole- noid (1).
q The current becomes constant, so the force pushing piston (2) is also constant. q If the main pump pressures (PP1) and (PP2) are low, the combined force of the pump pres- sure and the PC-EPC valve solenoid (1) is weaker than the spring set force, so spool (3) is balanced at a position to the left. q The port (C) is connected to the drain pressure of the port (D), and the large diameter end of the servo piston (9) also becomes the drain pressure (PT) through the LS valve. 24 PC210, 230, 240-8