10 Structure, function and maintenance standard UEN00099-00 (2) When the main pump is under heavy load q If the emergency pump drive switch is turned on in the same way as in above, the command current (X) sent to PC-EPC valve solenoid (1) becomes constant. q The curve resulting when the emergency pump drive switch is ON is situated further to the left (B) than when the pump controller is normal (A). q For this reason, the force of piston (2) pushing spool (3) is constant. q If main pump pressures (PP1) and (PP2) increase, spool (3) moves further to the right than when the main pump load is light, and is balanced at the position in the figure above.
q In this case, the pressure from port (B) flows to port (C), so servo piston (9) moves to the right (smaller pump delivery) and stops at a position to the further to the right then when the load on the pump is light. q When the emergency pump drive switch is turned on, too, the pump pressure (PP) and pump delivery (Q) have a relationship as shown with the curve in the figure correspond- ing to the current sent to the PC-EPC valve solenoid through the resistor. PC210, 230, 240-8 25