Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Functions and operation by valve

10 Structure, function and maintenance standard UEN00100-00 1. Arm valve 2. R.H. travel valve 3. Swing valve 4. Boom valve 5. L.H. travel valve 6. Bucket valve 7. Service valve 1 8. Service valve 2 9. Service valve 3 10. Arm spool 11. R.H. travel spool 12. Swing spool 13. Boom spool 14. L.H. travel spool 15. Bucket spool 16. Service spool 1 17. Service spool 2 18. Service spool 3 19. Pressure compensation valve 20. Suction valve 21. Check valve (for boom regeneration circuit) 22. Check valve (for arm regeneration circuit) 23. EPC valve (for switching main spool of merge- divider valve) 24. EPC valve (for switching LS spool of merge- divider valve) 25. LS shuttle valve 26. LS select valve 27.

Merge-divider valve 28. Arm quick return valve 29. Self pressure reducing valve 30. Travel junction valve 31. Back pressure valve 32. Cooler check valve 33. Main relief valve (bucket side) Set pressure: 34.9 ± 0.5 MPa{355.5 ± 5kg/cm 2 } When digging force increased: 37.5 ± 0.5 MPa{382 ± 5kg/cm 2 } 34. Main relief valve (arm side) Set pressure: 34.9 ± 0.5 MPa{355.5 ± 5kg/cm 2 } When digging force increased: 37.5 ± 0.5 MPa{382 ± 5kg/cm 2 } 35. Unload valve (bucket side) Cracking pressure: 2.5 ± 0.5 MPa{26 ± 5kg/cm 2 } 36. Unload valve (arm side) Cracking pressure: 2.5 ± 0.5 MPa{26 ± 5kg/cm 2 } 37. Safety-suction valve Set pressure: 24.5 ± 0.5 MPa{250 ± 5kg/cm 2 } 38.

Safety-suction valve Set pressure: 31.4 ± 0.5 MPa{320 ± 5 kg/cm 2 } 39. Safety-suction valve Set pressure: 38.2 ± 0.5 MPa{390 ± 5 kg/cm 2 } 40. 2-stage safety-suction valve Set pressure: 1 stage: 24.5 ± 0.5 MPa{250 ± 5 kg/cm 2 } 2 stage: 20.6 ± 0.5 MPa{210 ± 5 kg/cm 2 } PC210, 230, 240-8 21