UEN00100-00 10 Structure, function and maintenance standard Unload valve 1. When the unload valve is actuating 1. LS circuit 2. Valve 3. Pump circuit 4. Tank circuit 5. Spring Function Operation q Drains an oil discharge for the portion of the minimum pump swash plate angle while all control valves are in the holding. q Pressure of pump circuit (3) is received by the end of valve (2). q The pump pressure will correspond to a set load of spring (5) inside the valve (this pres- sure will be P1). q Since the control valve is in neutral position, pressure of LS circuit (1) is 0 MPa{0 kg/cm 2 }.
q Pressurized oil of pump circuit (3) stops at valve (2), and the pressure rises as no relief is available. q Since LS pressure is drained from the LS bypass valve, LS pressure C tank pressure C 0 MPa{0 kg/cm 2 }. q When this pressure becomes larger than the force of spring (5), valve (2) moves to the left. q Ports (b) and (c) are interconnected and the pump pressure flows to tank circuit (4). q The pressurized oil of LS circuit (1) passes from orifice (a) via port (c) and is drained to the tank circuit (4). q When actuated, LS pressure C tank pressure.
q Since the pump discharge pressure - LS circuit pressure during unloading is larger than the pump LS control pressure, the signal is output to minimize the pump swash plate angle. 22 PC210, 230, 240-8