Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Functions and operation by valve

10 Structure, function and maintenance standard UEN00100-00 q During operation (a work within a scope of dis- charge by a minimum swash plate angle), the discharge pressure for the portion of minimum pump swash plate angle is set to LS pressure + P1 pressure. 2. Operation of relief valve q When the cylinder reaches the stroke end, the main relief valve opens. q The pump delivery (Q) is relieved to the tank. (See the system diagram) q LS control differential pressure ( d PLS) of dis- charge for the portion of minimum swash plate angle will be equal to P1 pressure.

q The pump discharge pressure (PP) and LS pressure (PLS) become approximately the same as each has not flow at the upstream and downstream of the spool, and LS differen- tial pressure ( d PLS) becomes 0 kg/cm 2 . q As LS differential pressure ( d PLS) is lower than the LS set pressure of LS valve, LS valve is actuated to maximize the pump swash plate angle. q Mechanically, operation of PC valve have the prevalence to that of LS valve. q The pump is held at a minimum swash plate angle by the cut-off function of PC valve. PC210, 230, 240-8 23