UEN00100-00 10 Structure, function and maintenance standard Introduction of LS pressure 1 1. Hydraulic pump 2. Main spool 3. Pressure compensation valve 4. Valve 5. Check valve 6. LS circuit 7. LS shuttle valve Function q Introduces the upstream pressure (down- stream pressure of the spool meter-in) of pres- sure compensation valve (3) and leads to LS shuttle valve (7) as the LS pressure. q Connected to actuator port (B) via valve (4), and makes LS pressure C actuator load pres- sure. q Inlet pore (a) inside main spool (2) has a small diameter concurrently serving as a throttle.
Operation q When main spool (2) is operated, the pump pressure enters port (c) via inlet pore (a) and is led to the LS circuit. q When the pump pressures rises to reach the load pressure of port (B), check valve (5) opens. 24 PC210, 230, 240-8