Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Functions and operation by valve

UEN00100-00 10 Structure, function and maintenance standard Pressure compensation valve 1 1. During independent operation and under maximum load pressure (If the load pressure is higher than other work equipment during a combined operation) 1. Hydraulic pump 2. Valve 3. Shuttle valve 4. Piston 5. Spring 6. LS shuttle valve Function q Pressure compensation valve works as the load check valve. q As principle, port (C) and spring chamber (E) are not interconnected in an integrated pres- sure compensation valve. q If the pump pressure (LS pressure) is lower than the load at port (c), shuttle valve (3) in pressure compensation valve piston (4) inter- connects spring chamber (E) and port (C).

q If high peak pressure is generated at port (C), valve (7) does not collide with the valve cham- ber. q With a bucket valve, etc., port (C) and spring chamber (E) are designed to interconnect before valve (7) is seated. q The force of spring (5) operates piston (4) and valve (2) to the closing direction. q High stress may occur when valve (2) collides with valve chamber seat portion (C) if a high peak pressure is generated in the actuator cir- cuit or repetitive peak pressure occurs continu- ously (example: when using the breaker). Integrated pressure compensation valve q To prevent this, a pressure compensation valve with integrated valve (2) and piston (4) is used.

q With the present machine, this device is adopted for the bucket valve (cylinder bottom) and the service valve. 26 PC210, 230, 240-8