10 Structure, function and maintenance standard UEN00100-00 2. When compensated (If the load pressure is lower than other work equipment during a combined operation) Function q The pressure compensation valve closes under LS pressure of port (D), and the spool meter-in downstream pressure of port (B) becomes equivalent to the maximum pressure of other work equipment. q Since the spool meter-in upstream pressure of port (A) is the pump pressure, the spool meter- in differential pressure [upstream pressure port (A) pressure]–downstream pressure [port (B) pressure] becomes equivalent to all the spools in operation. q Pump flow is divided according to the ratio of the meter-in opening area.
Operation q Spring chamber (E) is interconnected to port (D). q Piston (4) and valve (2) operate in the closing direction (to the right) under the LS circuit pres- sure from other work equipment of port (F). q Valve upstream pressure (= spool meter-in downstream pressure) of port (B) is controlled with LS pressure. PC210, 230, 240-8 27