Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Functions and operation by valve

UEN00100-00 10 Structure, function and maintenance standard 3. Pressure compensation valve area ratio Function q The state of division changes according to the area ratio of pressure compensation portion (A1) and (A2). Area ratio = (A2)/(A1) q If area ratio = 1 : The spool meter-in downstream pressure will be equal to the maximum load pressure, and the pressure will be divided according to the opening area ratio. q If area ratio = 1 or over : The spool meter-in downstream pressure will be greater than the maximum load pressure, and the pressure will be divided smaller than the opening area ratio. q If area ratio = 1 or under :

The spool meter-in downstream pressure will be smaller than the maximum load pressure, and the pressure will be divided greater than the opening area ratio. 28 PC210, 230, 240-8