Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Functions and operation by valve

10 Structure, function and maintenance standard UEN00100-00 Pressure compensation valve inner shuttle valve 1 1. If holding pressure at port (A) is larger than LS pressure in the springing chamber (B) 1. Hydraulic pump 2. Valve 3. Pressure compensation valve inner shuttle valve 4. Piston Function q Shuttle valve (3) is pushed to the right by port (A) pressure and cuts off interconnection between ports (A) and (C). q Holding pressure at port (A) is led to the spring chamber (B) to push piston (4) to the left so that piston (4) and valve (2) will not be sepa- rated. PC210, 230, 240-8 29