10 Structure, function and maintenance standard UEN00100-00 Merge-divider valve 1 1. When flows from the pumps merge [if merge-divider selector signals (IS1) and (IS2) are OFF] 1. Main spool 2. Spring 3. LS spool 4. Spring 5. LS circuit (bucket side) 6. LS circuit (bucket side) 7. LS circuit (arm side) 8. LS circuit (arm side) 9. EPC valve (for main spool) 10. EPC valve (for LS spool) Function q Merges pressurized oil (P1) and (P2) dis- charged from the two pumps at ports (E) and (F) and sends to necessary control valve. q Merges pressurized oil (P1) and (P2) dis- charged from the two pumps or divides (to respective control valve group). q Merges and divides LS circuit pressure.
q Since selector signal (IS2) is OFF for LS spool (3), it is pressed to the right by spring (4), and ports (A) – (D) and ports (B) – (C) are intercon- nected. q Since selector signal (IS1) is OFF, output pres- sure from EPC valve is 0 kg/cm 2 . Operation q Forwards LS pressure led from respective con- trol valve spools to LS circuits (5), (6), (7) and (8) to all the pressure compensation valves. q Main spool (1) is pressed to the right by spring (2) and ports (E) and (F) are interconnected. PC210, 230, 240-8 35