Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Functions and operation by valve

UEN00100-00 10 Structure, function and maintenance standard 2. When flows from the pumps merge [if merge-divider selector signals (IS1) and (IS2) are ON] Operation q Selector signal (IS1) turns ON, and output pressure from the EPC valve shifts main spool (1) to the left, and ports (E) and (F) are divided. q Pressurized oil discharged from the two pumps are sent to respective control valves. P1 pressure: To bucket, L.H. travel, and boom P2 pressure: To swing, R.H. travel, and arm q When selector signal (IS2) is turned ON, LS spool (3) too shifts to the left under the output pressure from the EPC valve, interconnects ports (A) and (C) and divides other ports.

q Forwards LS pressure led from each control valve spool to LS circuits (5), (6), (7) and (8) to respective control valves. 36 PC210, 230, 240-8