10 Structure, function and maintenance standard UEN00100-00 2. During neutral and when load pressure (P2) is low a When load pressure (A2) is lower than self pressure reducing valve output pressure (PR) 3. When load pressure (P2) is high q Load pressure (A2) increases with the opera- tion of digging, etc., and the pump discharge increases accordingly. q Valve (7) is pressed to the closing direction of circuit between ports (P2) and (A2) by spring (8) and under pressure (PR) (which is 0 MPa{0 kg/cm 2 }). q Pressure (P2) increases to [( φ d area x P2 pres- sure) > force of spring (8) + ( φ d area x PR pres- sure)]., and valve (7) moves to the right to the stroke end.
q As a result, opening between ports (P2) and (A2) increases, and the pass resistance reduces, reducing the engine horsepower loss. q When pressurized oil flows in from port (P2), a balance is reached due to [( φ d area x P2 pres- sure) = force of spring (8) + ( φ d area x PR pres- sure)]. q When pressure (PR) rises above the set pres- sure, poppet (11) opens. q Adjusts valve (7) opening to keep pressure (P2) at a constant level over pressure (PR). q Pressurized oil flows from port (PR) to orifice (a) in spool (14), then flows to seal drain port (TS) from poppet (11) opening. q When pressure (PR) rises above the set pres- sure, poppet (11) opens.
q Differential pressure is generated before and after orifice (a) in spool (14) and then spool (14) moves to close the pass between ports (P2) and (PR). q Pressurized oil flows from port (PR) to orifice (a) in spool (14), then flows to seal drain port (TS) from poppet (11) opening. q Differential pressure is generated before and after orifice (a) in spool (14) and then spool (14) moves to close the pass between ports (P2) and (PR). q Pressure (P2) is reduced by the opening at this time and adjusted to a constant pressure (the set pressure) and supplied as pressure (PR).
q Pressure (P2) is reduced by the opening at this time and adjusted to a constant pressure (the set pressure) and supplied as pressure (PR). PC210, 230, 240-8 39