UEN00100-00 10 Structure, function and maintenance standard 4. When abnormally high pressure is gen- erated q If pressure (PR) of self pressure reducing valve becomes abnormally high, ball (16) con- tracts spring (15) and becomes separated from the seat. q Allows the pressurized oil to (TS) from port (PR) and lowers pressure (PR). q Protects PPC valve, solenoid valve and other devices from abnormal pressure. 40 PC210, 230, 240-8