10 Structure, function and maintenance standard UEN00100-00 2-stage safety-suction valve [Installed to port (B) of the service valve] 1 1. Spring 2. Piston 3. Spring 4. Holder Function q Enables to provide the safety valve set pres- sure in two stages, and make the low-pressure setting smaller. 1. If pilot pressure is OFF (high-pressure setting) q Since pilot pressure (P) is OFF, piston (2) is pressed to the left by spring (3). [Spring (1) installed load q Enables to relieve a load without lever opera- tion if high load is applied to the cylinder. q Improves work efficiency and reduces machine body vibration. q Spring (1) installed load becomes maximum and the set pressure rises.
q Passage (B) is interconnected to the drain cir- cuit via passage (C) and chamber (D). q The safety set pressure is determined by spring (1) installed load. Operation PC210, 230, 240-8 55