UEN00160-00 10 Structure, function and maintenance standard Operation q The relationship of the position of spool (1) and body (10) [fine control hole (f) is in the middle between drain chamber (D) and pump pres- sure chamber (PP)] does not change until retainer (9) contacts spool (1). 1. When in neutral q Ports (A) and (B) of the control valve and ports (P1) and (P2) of the PPC valve are connected to drain chamber (D) via fine control hole (f) in spool (1). q Metering spring (2) contracts in proportion to the stroke of the control lever. q Pressure at port (P1) also rises in proportion to the stroke of the control lever.
q In this way, the control valve spool moves to a position where the pressure of chamber (A) (same as pressure at port (P1)) and the force of the return spring of the control valve spool are balanced. 2. During fine control (Neutral o fine control) q When piston (4) is pushed by disc (5), retainer (9) is pushed, spool (1) is also pushed by metering spring (2), and moves down. q When fine control hole (f) is shut off from drain chamber (D), it is almost simultaneously inter- connected to pump pressure chamber (PP). q Pilot pressurized oil of the control pump is led to port (A) from port (P1) via fine control hole (f).
q When the pressure at port (P1) becomes higher, spool (1) is pushed back and fine con- trol hole (f) is shut off from pump pressure chamber (PP). At almost the same time, it is connected to drain chamber (D) to release the pressure at port (P1). q As a result, spool (1) moves up and down until the force of metering spring (2) is balanced with the pressure at port (P1). 28 PC210, 230, 240-8