Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — PPC valve

10 Structure, function and maintenance standard UEN00160-00 Function Operation q The EPC valve consists of the proportional solenoid portion and the hydraulic valve por- tion. 1) When signal current is 0 (coil is deenergized) q When it receives signal current (i) from the pump controller, it generates the EPC output pressure in proportion to the size of the signal, and outputs it to the control valve. q When there is no signal current flowing from the controller to coil (14), coil (14) is deener- gized. q Spool (11) is pushed to the right by spring (12). q Port (P) closes and the pressurized oil from the front pump does not flow to the control valve.

q The pressurized oil from the control valve is drained to the tank via port (C) and port (T). PC210, 230, 240-8 43