10 Structure, function and maintenance standard UEN00103-00 Function 1) Control method in each mode P mode, E mode, and ATT mode q This function allows the operator to select engine torque (T) and pump absorption torque depending on the work contents of the machine. Five modes of P, E, L, ATT, and B (three modes of P, E, and L for machines with “No ATT” specified) are specified as working modes. To select a working mode, use the working mode selector switch of the machine monitor. q Matching point:
Models Mode PC210/230-8 P and ATT (Work) 107.0 kW/1,800 rpm {143 HP/1,800 rpm} E 91.9 kW/1,800 rpm {123 HP/1,800 rpm} q The pump controller controls the pump so that it can absorb all the torque at the output points of the engine depending on the pump absorp- tion torque specified for each mode, rotation set by the fuel control dial, and actual engine speed. Models Mode PC240-8 P and ATT (Work) 120.0 kW/1,850 rpm {161 HP/1,850 rpm} E 109.8 kW/1,850 rpm {147.3 HP/1,850 rpm} q In P, E, or ATT mode, engine speed is always controlled so that it is kept around the match- ing point specified for each mode. q If the pump load increases and the pressure rises, engine speed (N) lowers.
If it happens, the engine speed is increased to around the matching point, allowing the pump controller to decrease pump delivery (Q). On the contrary, the pump load decreases and the pressure lowers, the pump controller continues to increase pump delivery until the engine speed reaches around the matching point. PC210, 230, 240-8 13