Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Electrical control system

UEN00103-00 10 Structure, function and maintenance standard B mode and L mode Mode B L Partial output point 75% 70% Models Mode PC210/230-8 B 80.9 kW/1,780 rpm {108 HP/1,780 rpm} L 73.6 kW/1,800 rpm {99 HP/1,800 rpm} Models Mode PC240-8 B 103 kW/1,750 rpm {138 HP/1,750 rpm} L 80.9 kW/1,870 rpm {108 HP/1,870 rpm} q q In B or L mode, engine output is controlled to a constant level. q The controller controls the pump absorption torque to decrease the engine speed while keeping the engine torque at a constant level along the equal engine horsepower curve.

q The controller controls pump delivery (Q) so that the engine torque can be kept at a con- stant level along the equal engine horsepower curve. 14 PC210, 230, 240-8