10 Structure, function and maintenance standard UEN00103-00 1) LS control function 3) 2-stage relief function q Depending on the operation condition of the actuator, this function changes the pressure output from the LS-EPC valve to LS valve to change the change point (LS set differential pressure (DLS)) of the pump discharge in the LS valve. q The relief pressure in the normal work is 34.8 MPa {355 kg/cm 2 }. If the 2-stage relief function is turned on, however, the relief pressure rises to about 37.2 MPa {380 kg/cm 2 }. By this opera- tion, the hydraulic force is increased further.
q By this operation, the start-up time of the pump discharge is optimized and the composite operation and fine control performance is improved. Operating condition for turning on 2- stage relief function Relief pressure During travel When swing lock switch is turned to the ON position When boom is lowered When power maximizing function is turned on When L mode is operated 34.8 MPa {355 kg/cm 2 } O 37.2 MPa {380 kg/cm 2 } q This function increases PC-EPC current (J) to reduce the flow rate in the relief state, improv- ing fuel consumption.
2) Cut-off function Operating condition for turning on cut-off function When the average value of the front and rear pressure sensors is above 27.9 MPa {285 kg/cm 2 } with the power maximizing function off. The cut-off function does not work, however, while the machine is travelling in A mode, swing lock switch is in the “ON” position. PC210, 230, 240-8 17