Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Electrical control system

UEN00103-00 10 Structure, function and maintenance standard 3. Power maximizing function Function q The power maximizing function allows the operator to increases power for a certain time by operating the left knob switch. q These settings are automatically reset after 8.5 seconds when the switch is pressed. q This function is used to increase digging force for a certain period of time (e.g., when digging up a large rock). q Pressing the L.H. knob switch in P, E, or ATT mode increases a hydraulic force by approxi- mately 7% and horsepower by approximately 3%, increasing a digging force. At this time, each function is automatically set as shown below.

Function Setting Engine and pump control Matching at rated output point 2-stage relief function 34.8 MPa {355 kg/cm 2 } O 37.2 MPa {380 kg/cm 2 } Software cut-off function Cancel 18 PC210, 230, 240-8