Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Electrical control system

10 Structure, function and maintenance standard UEN00103-00 4. Auto-deceleration function Function q The auto-deceleration function automatically reduces the engine speed to its medium speed range when the all control levers are set in NEUTRAL while waiting for a dump truck or work to reduce the fuel consumption and noise. q If any lever is operated, the engine speed instantly returns to the speed set with the fuel control dial. Operation When control levers are set in neutral q If all the control levers are kept to NEUTRAL for 4 sec.

during operation at a engine speed above a decelerator operation level (approxi- mately 1,400 rpm), this function lowers the engine speed to the deceleration operation level (approximately 1,400 rpm) and keeps it until you operate any lever. When any control lever is operated q If you operate any control lever while the engine speed is kept at the deceleration opera- tion level, the engine speed instantly rises to the level set with the fuel control dial. PC210, 230, 240-8 19