Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Monitor system

UEN00103-00 10 Structure, function and maintenance standard Idle stop guidance function 1 This function displays guidance to control unneces- sary fuel consumption. It is displayed only when all the following conditions are met. q Energy saving guidance display of the service menu is specified to ON. q No operation is made at least 5 min. and the engine is running at idle. q No error or caution (excluding low hydraulic oil temperature) is occurring. This screen switches to the normal screen if one of the following conditions occurs.

q When the lever is operated q When F5 is pressed q When an error or caution occurs When you switch to the normal screen by pressing F5, this screen does not appear even if the engine continues to run at idle. If the engine continues to run at least five min. after operating the lever, this screen appears again. 54 PC210, 230, 240-8