Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Monitor system

10 Structure, function and maintenance standard UEN00103-00 Service meter check function 1 Display LCD check function 1 q If you continuously pressing auto-deceleration switch (1) and buzzer cancel switch (2) at the same time when setting the starting switch to the OFF position, the service meter will appear on the screen in 3 to 5 sec. q Continuously pressing the buzzer cancel switch (1) and F2 at the same time on the password input screen or normal screen causes the entire LCD to light in white. Release F2 and buzzer cancel switch in order. If any part of the display is black, the LCD is broken. q When these switches are released, the LCD goes out.

a Continuous operation of the machine monitor may display blue bright spots on this screen; it is quite normal. q Pressing any function switch returns to the pre- vious screen. PC210, 230, 240-8 55