20 Standard value table UEN00227-00 PC240LC, 240NLC-8 PC210, 230, 240-8 11 Applicable model PC240LC, 240NLC-8 Cate- gory Item Measurement condition Unit Standard value for new machine Judgement criteria Engine speed 2 pumps at relief • Engine coolant temperature: Within operating range • Hydraulic oil temperature: Within operating range • Engine at high idle • Power mode (P) • Arm IN relief condition rpm 1,940 ± 100 1,940 ± 100 At 2-pump relief + power max. • Engine coolant temperature: Within operating range • Hydraulic oil temperature: Within operating range • Engine at high idle • Working mode:
P mode • Arm IN relief + Left knob switch ON rpm 1,950 ± 100 1,950 ± 100 Speed when auto- deceleration is operated • Engine at high idle • Auto-deceleration switch in ON condition • All control levers in NEUTRAL condition rpm 1,400 ± 100 1,400 ± 100 Spool stroke Boom control valve • Engine stopped • For measuring point, see Control valve.
Raise mm 11.5 ± 0.5 11.5 ± 0.5 Lower mm 9.5 ± 0.5 9.5 ± 0.5 Arm control valve IN mm 11.5 ± 0.5 11.5 ± 0.5 OUT mm 9.5 ± 0.5 9.5 ± 0.5 Bucket control valve CURL, DUMP mm 9.5 ± 0.5 9.5 ± 0.5 Swing control valve LH, RH travel mm 9.5 ± 0.5 9.5 ± 0.5 Travel control valve Forward, Reverse mm 9.5 ± 0.5 9.5 ± 0.5 Travel of control levers Boom control lever • Engine stopped • Control lever grip at center • Max.
reading up to stroke end (except lever play in NEUTRAL position) Work equipment Travel mm 85 ± 10 85 ± 10 Arm control lever mm 85 ± 10 85 ± 10 Bucket control lever mm 85 ± 10 85 ± 10 Swing control lever mm 85 ± 10 85 ± 10 Travel control lever mm 115 ± 12 115 ± 12 Play of control lever Work equipment mm Max. 15 Max. 20 Travel mm Max. 20 Max. 25